On Fri, Sep 25, 2009 at 11:17:57AM -0500, David A. Kotz wrote:
> >> Type precheck passed.
> >> *** No possible mapping for nfrouter
> >> No links of type ethernet found! (2 requested)
Whoops, I didn't address this error. Does your interface_capabilities table
have something like this for the netfpga interface type? That is the most
likely src of problem here...
mysql> select * from interface_capabilities where type='nf2';
+------+-------------------+----------+
| type | capkey | capval |
+------+-------------------+----------+
| nf2 | ethernet_defspeed | 1000000 |
| nf2 | protocols | ethernet |
+------+-------------------+----------+
2 rows in set (0.00 sec)
> Sorry if I'm being dense, but I don't think I requested the feature. I
> took your tutorial NS file and changed only the type from "netfpga2" to
> my "netfpga".
My fault. For subnode hosts, I see that the parser adds a 1.0-weight desire
for a feature named "hosts-$type" -- where type is the subnode type -- in your
case, "netfpga". So yes, you will need to add that feature as I described in
the earlier mail.